基于场景集的危险气体检测报警仪选址方法
章博1,王志刚2,王彦富1,蔡文斌3,邹牛洋1
(1.中国石油大学机电工程学院,山东青岛 266580;2.广西天然气管道有限责任公司,广西北海 536000;3.西安石油大学石油工程学院,陕西西安 710065)
摘要:
传统以典型或等概率泄漏场景为代表开展危险气体检测报警仪选址的做法未能体现装置真实风险,报警仪的探测效率较低。提出一种基于场景集的危险气体检测报警仪选址方法。融合泄漏源工况和风场等重要随机因素生成可能发生的泄漏场景,并定量预测场景发生概率。以概率加权法建立报警仪选址方案的定量评价指标,结合报警仪数量约束构建随机优化模型。结合气体扩散经验模型定义泄漏场景风险指数,在保证风险覆盖率的前提下,优选最大可信场景进行CFD数值模拟。基于量子粒子群算法实现优化模型的定量求解。以某柴油加氢装置为例,采用该方法进行硫化氢检测报警仪选址优化。结果表明,通过该方法获得的最优选址方案与原布置方案相比可较大程度地提高探测效率。
关键词:  泄漏场景集  气体检测报警仪  选址优化  随机优化  炼油装置
DOI:10.3969/j.issn.1673-5005.2016.06.020
分类号::X928.03; X928.5; X937
文献标识码:A
基金项目:山东省自然科学基金项目 (ZR2016EEM27);国家自然科学基金项目(51409260);中央高校基本科研业务费专项(2012-487);2012年度山东省安全生产科技发展计划项目(LAK2012-6)
An approach to placement optimization of gas detectors based on leakage scenario set
ZHANG Bo1, WANG Zhigang2, WANG Yanfu1, CAI Wenbin3, ZOU Niuyang1
(1.College of Mechanical and Electronic Engineering in China University of Petroleum, Qingdao 266580, China;2.Guangxi Gas Pipeline Company Limited, Beihai 536000, China;3.Petroleum Engineering Academy, Xi 'an Shiyou University, Xi 'an 710065,China)
Abstract:
The traditional gas detector placement method using typical or equal probability leakage scenarios can not reflect the actual risk, and the detection efficiency is also low. Basing on the approximate real leakage scenario set, this article proposes a new approach to gas detector placement optimization. It combines leaking condition and wind field to build leakage scenes that will probably occur and predicts the probability of each leakage scenario quantatively. The probability weighting method was applied to establish the quantitative evaluation index for the detector layout. With the constraint of detector number, the stochastic optimization model was developed. The gas leakage empirical model was also integrated to define the risk index for leakage scenario and the most credible scenario was selected to perform a CFD-based dispersion simulation. To obtain the optimal gas detectors placement efficiently, the quantum particle swarm optimization(QPSO) was employed to solve this model. The method mentioned above was applied to the optimization of hydrogen sulfide detectors for a diesel hydrogenation unit. The results demonstrate that the optimal hydrogen sulfide detectors placement can significantly improve the detection efficiency compared with the original layout.
Key words:  leakage scenario set  gas detector  placement optimization  stochastic programming  oil refinery installations